add images and text
This commit is contained in:
parent
e700fe3b9c
commit
ca1bd2becf
7 changed files with 32 additions and 2 deletions
BIN
maerospace/images/box_1.jpeg
Normal file
BIN
maerospace/images/box_1.jpeg
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 162 KiB |
BIN
maerospace/images/box_1.png
Normal file
BIN
maerospace/images/box_1.png
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 208 KiB |
BIN
maerospace/images/box_2.jpeg
Normal file
BIN
maerospace/images/box_2.jpeg
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 154 KiB |
BIN
maerospace/images/box_2.png
Normal file
BIN
maerospace/images/box_2.png
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 207 KiB |
BIN
maerospace/images/rack.jpeg
Normal file
BIN
maerospace/images/rack.jpeg
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 483 KiB |
BIN
maerospace/images/rack_annotated.png
Normal file
BIN
maerospace/images/rack_annotated.png
Normal file
Binary file not shown.
|
After Width: | Height: | Size: 271 KiB |
|
|
@ -6,7 +6,6 @@
|
||||||
"PoE": ("Power over Ethernet",),
|
"PoE": ("Power over Ethernet",),
|
||||||
))
|
))
|
||||||
|
|
||||||
|
|
||||||
#align(center)[#text(size:20pt)[EET Deployment Overview on Maerospace
|
#align(center)[#text(size:20pt)[EET Deployment Overview on Maerospace
|
||||||
Equipement]]
|
Equipement]]
|
||||||
|
|
||||||
|
|
@ -18,4 +17,35 @@ The type of equipement is also not limited to processing servers and may include
|
||||||
= Measurement Equipement
|
= Measurement Equipement
|
||||||
|
|
||||||
The measurement equipement (thereafter refered to as the #acr("EET") box or simply the box) comprises a Hall Effect sensor, a digitizer, and a #acr("SBC").
|
The measurement equipement (thereafter refered to as the #acr("EET") box or simply the box) comprises a Hall Effect sensor, a digitizer, and a #acr("SBC").
|
||||||
The box is power through #acr("PoE") and thus uses the same Ethernet cable for power and communication.
|
The box is powered through #acr("PoE") and thus uses the same Ethernet cable for power and communication.
|
||||||
|
|
||||||
|
#figure(
|
||||||
|
grid(
|
||||||
|
columns: (1fr,1fr),
|
||||||
|
align(center)[#image("images/box_1.png", width:90%)],
|
||||||
|
align(center)[#image("images/box_2.png", width:90%)],
|
||||||
|
),
|
||||||
|
caption: "Example of EET box. Front and back views.",
|
||||||
|
)<fig:box>
|
||||||
|
|
||||||
|
= Planned Installation
|
||||||
|
|
||||||
|
The initial installation will deploy 6 boxes to measure DC power at different point in the system.
|
||||||
|
Because the goal is to remain minimaly invasive, only the exposed DC cables will be monitored.
|
||||||
|
The measurement points are:
|
||||||
|
|
||||||
|
+ 2 DC cable pairs from the power supply on the right (marked 1 on @fig:rack).
|
||||||
|
+ 3 DC cables from the power supply on the left (marked 2 on @fig:rack).
|
||||||
|
+ The gateway computer outside on the rack (not marked on @fig:rack).
|
||||||
|
|
||||||
|
#figure(
|
||||||
|
image("images/rack_annotated.png", width:80%),
|
||||||
|
caption: "Some of the measurement points.",
|
||||||
|
)<fig:rack>
|
||||||
|
|
||||||
|
The following equipement will be added to the system:
|
||||||
|
|
||||||
|
- 5 EET measurement boxes.
|
||||||
|
- 5 replacement cables for the cables that are monitored.
|
||||||
|
- 1 PoE switch.
|
||||||
|
- #text(red)[1 on-premis aggregator server]
|
||||||
|
|
|
||||||
Loading…
Add table
Add a link
Reference in a new issue